Material |
Frame,impeller :plastics |
Life expectancy |
40,000hours ï¼? L10:Survival rate:90% at 60â?? , rated voltage, and continuously run in a free air stateï¼? |
Motor Protection System |
Current blocking function (with reverse polarity protection) |
Dielectric Strength
------------------------------------
Insulation Resistance
|
50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) -------------------------------------------------------------------------------------------------------------- 10MO or more at 500VDC megger (between lead conductor and frame) |
Sound Pressure Level (SPL) |
Measured at 1m from the air inlet |
Storage Temperature
--------------------------------------
Operating Temprature
|
-30ºC to +70ºC -------------------------------------------------------------------------------------------------------------- -10ºC to +60ºC 9S1212H4011
-30ºC to +70ºC 9S1212F4011ï¼?9S1212M4011ï¼?9S1212L4011 (Non-condensing) |
Lead Wire |
(+)red, (-)black Sensor: yellow |

 |
Model No. |
Rated Voltage (V) |
Operating voltage range (V) |
Rated current (A) |
Rated input (W) |
Rated rotaing speed (min-1) |
Air flow (m3/min) |
Static pressure (Pa) |
Noise (dB[A]) |
Mass (g) |
9S1212H4011
|
12
|
5.0 to 13.2
|
0.39
|
4.68
|
2,700
|
2.45 (86.5CFM)
|
45.2 (0.18inchH2O)
|
36
|
140
|
|