As the computer industry continues to accelerates its pace towards implementing liquid cooling solutions, pumps have become a pivotal concern for the adoption of such systems in mission critical machines. Small size, low or no maintenance, similar to that afforded by fans, and extended reliability are prerequisites for the successful transition from air to liquid cooling systems.
As the computer industry continues to accelerates its pace towards implementing liquid cooling solutions, pumps have become a pivotal concern for the adoption of such systems in mission critical machines. Small size, low or no maintenance, similar to that afforded by fans, and extended reliability are prerequisites for the successful transition from air to liquid cooling systems.
Retention Mechanism
The MCP350 can either be installed with the built-in neoprene pad featuring a peel-off adhesive back, or permanently with thru-bolts.
Introducing the MCP350 pump: despite a remarkably small footprint of 2.4" square, the MCP350 features an astounding 13ft of head to provide superior flow rates in today's most complex liquid cooled systems. The MCP350 is also a high reliability, high pressure industrial pump, featuring a 50,000 hour MTBF (5 year lifetime). Such reliability is afforded by the unique design of this pump, which contains only one moving part: the magnetically driven rotor/impeller spins on a single ceramic bearing, thus extending the life of this pump beyond existing standards.
The pump is completely plug-and-play, and connects directly to any computer power-supply through standard 4 pin power connectors. It's compact design, quiet and powerful motor make it ideally suited for heavy duty cooling in environments where space is at a premium.
Summary of benefits
Small Footprint: 2.4" x 2.4" x 1.5"
50,000 hours MTBF (Mean Time Between Failure) equivalent to 5 years lifetime.
Superior 12 Volts DC convenience: plugs into the computer power supply
The MCP350 can be used with full confidence in any MP servers, and high-end workstations.
Superior real world performance thanks to its high pressure characteristics (13ft of head). The MCP350 is particularly well adapted to the proliferation of daisy-chained liquid cooling devices in a single circuit: Multiple Processors, Chipset, Graphics, and Hard Drives.
Quiet Operation thanks to brushless motor: 24 to 26 dBA
3/8" barb fittings.
No maintenance when used with de-mineralized water, and anti-fungal additives (Our HydrX additive is recommended)
Quick installation with adhesive neoprene pad, or permanent installation with screws and grommets.
RPM sensor plugs to 3 pin motherboard fan connectors and reports impeller rotational speed
As you can see in the photos, the top has molded fittings. They are not removable. Only way to have fitting options on a DDC pump is to purchase an aftermarket top for the DDC pump.
by PPCs Tech
8 years ago00
Answer this Question
Ask a New Question
Configure Swiftech MCP350 12 VDC DDC Pump
Pump Cable Sleeving
Sleeving Materials
Pump Top Options
OR
product
https://www.performance-pcs.com/swiftech-mcp350-12-vdc-ddc-pump-mcp350.html2793Swiftech MCP350 12 VDC DDC Pumphttps://www.performance-pcs.com/media/catalog/product/t/m/tmpmcp355-01.gif99.9599.9500USDOutOfStock/Water Cooling/Pumps<p><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">As the computer industry continues to accelerates its pace towards implementing liquid cooling solutions, pumps have become a pivotal concern for the adoption of such systems in mission critical machines. Small size, low or no maintenance, similar to that afforded by fans, and extended reliability are prerequisites for the successful transition from air to liquid cooling systems.</span></p> <p><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">As the computer industry continues to accelerates its pace towards implementing liquid cooling solutions, pumps have become a pivotal concern for the adoption of such systems in mission critical machines. Small size, low or no maintenance, similar to that afforded by fans, and extended reliability are prerequisites for the successful transition from air to liquid cooling systems.</span><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2"></span></p>
<p><strong><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Retention Mechanism</span></strong></p>
<p><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">The MCP350 can either be installed with the built-in neoprene pad featuring a peel-off adhesive back, or permanently with thru-bolts.</span></p>Swiftech00https://www.performance-pcs.com/media/catalog/product/t/m/tmpmcp350-installation.gif96.7700low-stockSwiftechBlackDDC12 VDC<p><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Introducing the MCP350 pump: despite a remarkably small footprint of 2.4" square, the MCP350 features an astounding 13ft of head to provide superior flow rates in today's most complex liquid cooled systems. The MCP350 is also a high reliability, high pressure industrial pump, featuring a 50,000 hour MTBF (5 year lifetime). Such reliability is afforded by the unique design of this pump, which contains only one moving part: the magnetically driven </span><a href="http://www.swiftnets.com/products/mcp350.asp#exploded" target="_blank"><span style="color: #800080; font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" color="#800080" face="tahoma,arial,helvetica,sans-serif" size="2">rotor/impeller</span></a><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2"> spins on a single ceramic bearing, thus extending the life of this pump beyond existing standards. </span></p>
<p><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">The pump is completely plug-and-play, and connects directly to any computer power-supply through standard 4 pin power connectors. It's compact design, quiet and powerful motor make it ideally suited for heavy duty cooling in environments where space is at a premium. </span></p>
<h1><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Summary of benefits</span></h1>
<ul>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Small Footprint: 2.4" x 2.4" x 1.5" </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">50,000 hours MTBF (Mean Time Between Failure) equivalent to 5 years lifetime. </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Superior 12 Volts DC convenience: plugs into the computer power supply </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">The MCP350 can be used with full confidence in any MP servers, and high-end workstations. </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Superior real world performance thanks to its high pressure characteristics (13ft of head). The MCP350 is particularly well adapted to the proliferation of daisy-chained liquid cooling devices in a single circuit: Multiple Processors, Chipset, Graphics, and Hard Drives. </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Quiet Operation thanks to brushless motor: 24 to 26 dBA </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">3/8" barb fittings. </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">No maintenance when used with de-mineralized water, and anti-fungal additives (Our HydrX additive is recommended) </span></li>
<li><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Quick installation with adhesive neoprene pad, or permanent installation with screws and grommets. </span></li>
<li style="font-family: tahoma,arial,helvetica,sans-serif;"><span style="font-size: small;" size="2">RPM sensor plugs to 3 pin motherboard fan connectors and reports impeller rotational speed</span></li>
</ul><table style="width: 404px;" id="table2" border="0" cellpadding="2" cellspacing="0">
<tbody>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Nominal voltage</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">12 V DC</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Operating voltage range</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">8 to 13.2 VDC</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Nominal power (@ 12 V)</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">8.3-12W</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Nominal current (@ 12 V)</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">.69-1 amps</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Nominal head (@ 12 V)</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">10.8 ft (3.3 m)</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Nominal discharge (@ 12 V)</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">~ 116 GPH (440 LPH)</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Connection size</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">3/8" barbs (10mm)</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Maximum pressure</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">22 PSI (1.5 BAR)</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Temperature range</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Up to 140°F (60°C)</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Electrical connector</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Molex 4 pin</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Weight</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">7.3 oz (207 gr.)</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Our noise measurement (non lab environment) </span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">24 ~ 26 dBA in a quiet room @ 2'</span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Motor type</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Electronically commutated, brushless DC<br /></span></td>
</tr>
<tr>
<td width="186"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Pump MTBF (Mean Time Between Failures)</span></td>
<td width="210"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">50,000 Hours</span></td>
</tr>
</tbody>
</table>
<div align="center"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2"> </span>
<p align="left"><span style="color: #800080; font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" color="#800080" face="tahoma,arial,helvetica,sans-serif" size="2"><b>P/Q curve</b><br /></span><img style="margin: 5px;" alt="MCP350 PQ Curve" src="http://www.swiftech.com/images/mcp350-pq-large.PNG" align="middle" border="0" /></p>
<p align="left"><b><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2">Dimensions</span></b></p>
<p align="left"><b><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2"> </span></b><img style="margin: 5px;" alt="MCP350 Dimensions" src="/pub/media/descriptions/2539-mcp350-dimensions.gif" align="middle" border="0" /></p>
</div>
<p align="left"><span style="font-family: tahoma,arial,helvetica,sans-serif; font-size: small;" face="tahoma,arial,helvetica,sans-serif" size="2"><b>Exploded View</b><br /></span><img style="margin: 5px;" alt="MCP350 Permanent Installation" src="/pub/media/descriptions/2539-MCP350-installation.gif" border="0" /></p>